1. Home
  2. Uncategorized
  3. Hygienic Wall Cladding for Veterinary Clinics and Animal Hospitals: Meeting RCVS Hygiene Standards

Hygienic Wall Cladding for Veterinary Clinics and Animal Hospitals: Meeting RCVS Hygiene Standards

A veterinary practice has to meet hospital-grade hygiene standards while its walls take abuse no human hospital would see. A 40kg dog shaking off after a bath, a stainless kennel bank dragged across a ward, claws on a prep-bay wall, a daily parvovirus-grade washdown: the fabric of a vet clinic is cleaned harder and hit harder than almost any other clinical building.

That is why hygienic wall cladding has become the standard finish for veterinary clinics and animal hospitals in the UK, and why the RCVS Practice Standards Scheme assessor will look closely at it. This guide covers what the RCVS requires of walls and floor junctions, how Jemiclad panels stand up to impact, scratching and chemical washdown, and which specification to use room by room, from kennels and isolation to surgical prep bays and theatre.

What the RCVS Practice Standards Scheme requires of your walls

The RCVS Practice Standards Scheme (PSS) is voluntary, but around two-thirds of UK practices are accredited and assessed every four years, with spot checks in between. Hygiene is one of the core standards every tier must meet, and the Practice Standards Manual is specific about the building fabric in in-patient and surgical areas.

In summary, the manual requires that:

  • Internal walls and floors of in-patient areas are impervious, so they can be thoroughly cleaned and disinfected.
  • The junction between floor and wall has a curved (coved) finish to aid cleaning, with the coving carried at least 75mm up the wall.
  • All joints in the flooring or coving are impervious and finished flush with the surface.
  • Stick-on coving is not acceptable.
  • In-patient facilities, including kennels and cages, are sturdy, escape-proof, free of injurious faults and easily cleanable.
  • The surgical area has easily cleanable surfaces and good illumination.

Assessors use judgement, but the direction is clear: painted plasterboard, tiled walls with grout, and anything with an open joint or a stuck-on skirting will raise questions. A seamless hygienic wall cladding system with a welded or overlapped coved base answers every one of those points in a single specification.

Beyond the manual, PSS assessment expects a written biosecurity and cleaning policy for each clinical area. Walls that can be cleaned to that policy without special care make the policy easier to write and far easier to evidence on the day.

Impact and scratch resistance: dogs, cages and trolleys

Human hospital wall protection is designed around trolley and bed impacts at a predictable height. Veterinary walls are hit at every height, from a Great Dane’s shoulder to a cat carrier swung onto a worktop, and they are scratched as well as struck.

Jemiclad hygienic wall cladding panels are designed to be impact resistant, providing durable wall protection for healthcare, commercial and high-traffic environments. Available in three different thicknesses, the panels offer flexibility to suit a range of project requirements.

For areas where scratches and scuffs are a particular concern, Jemiclad’s textured panels are the recommended option, offering enhanced scratch resistance while maintaining a hygienic, easy-to-clean surface.

 And damage that would chip a tile or dent a painted board is absorbed. Published data for the PVC range gives a notched impact strength of at least 4 kJ/m² (DIN EN ISO 179-1) and a flexural strength of at least 80 MPa (DIN EN ISO 178).

For kennels, wards and prep bays, specify the textured white finish. Jemiclad’s textured (anti-scuff) white panel is the scratch-resistant option in the range. The fine surface texture hides the micro-scratches that claws and cage edges leave on a high-gloss finish, so the wall keeps looking clean between deep cleans, while remaining fully non-porous and washable. Gloss finishes are better suited to reception, consult rooms and theatre where the surface is wiped rather than scoured.

Where walls meet floors behind kennel banks, Jemiclad panels can be thermoformed down into a coved base and bonded over the vinyl, so there is no exposed trim edge for a dog to chew or a mop to catch.

Chemical washdown compatibility

Veterinary disinfection is harsher than most human healthcare cleaning because the target pathogens are tougher. Canine parvovirus, feline calicivirus, ringworm spores and MRSA/MRSP all survive on surfaces, and practices rely on oxidising and chlorine-based agents to deal with them: sodium hypochlorite (bleach) solutions, peroxygen compounds, quaternary ammonium products and, in some areas, alkaline degreasers.

Those chemicals attack paint, grout, sealant and many laminates. Jemiclad PVC panels are tested against a wide range of cleaning media; published resistance data shows good resistance (less than 1% weight change) to sodium hypochlorite at 40%, hydrochloric acid at 35%, sulphuric acid at 96%, phosphoric acid at 95% and 10% caustic soda, at both 20°C and 60°C. Water absorption is below 0.08% after seven days, so the surface does not swell or soften under daily wet cleaning.

Because the hot welded joint is the same PVC as the panel, the seam has the same resistance as the face. That is the practical difference between a seamless system and a trimmed one: with a jointing trim, the sealant line is usually the first thing a strong disinfectant degrades.

Two cautions apply. Jemiclad PVC has a maximum working temperature of 60°C, so steam cleaning and hot-wash equipment should be kept within that limit, and solvent-based products (acetone, benzene, xylene) should be avoided on any PVC surface. The full chemical resistance table is on the Technical Documents page, so your cleaning protocol can be checked against it product by product.

Room-by-room: where to use hygienic wall cladding in a veterinary practice

AreaHygiene and wear demandsRecommended Jemiclad specification
Kennels and cattery wardsClaws, cage impacts, urine, daily bleach washdownTextured white, full height, hot welded joints, thermoformed corners, flash cove overlap base
Isolation wardHighest-risk pathogens, deep cleans between patientsTextured or gloss, full height, welded to safety vinyl for a fully sealed envelope
Surgical prep bayClipping, scrubbing, splashes, frequent disinfectionFull height seamless cladding, coved base, gloss or textured
Operating theatreSterile surgery, wipe-down cleaning, good illuminationGloss white or pale colour, full height, hot welded, thermoformed corners
Dental and imagingWater spray, contrast agentsFull height seamless cladding around the chair or table
Consult roomsModerate wear, client-facingDado-height cladding in a colour from the range, start and edge trim at top
Grooming and hydrotherapyStanding water, shampoo, heavy dogsFull height, flash cove overlap base, textured finish
Reception and waitingImpact from carriers and leads, visible to clientsDado-height panels in brand colours

A full-height seamless installation in the wet and in-patient rooms, with dado-height panels in public areas, is the combination most practices choose. It puts the budget where the RCVS assessor and the cleaning team need it.

Seamless installation: how the RCVS coving rule is met

The RCVS requirement for impervious walls, a coved floor junction of at least 75mm and flush, impervious joints is met by three Jemiclad installation details.

Hot welded joints. Panels are set with a 2mm gap and fused with a colour-matched PVC weld rod, trimmed flush. There is no lip, no sealant line and no trim for hair, urine or disinfectant to sit behind. Jemiclad also supplies 2-part jointing trims for dry, low-risk areas, but in kennels, prep and theatre the specification should call for hot welding.

Thermoformed corners. Every internal and external corner is heat-formed on site from the panel itself, removing the vertical corner joint that is the usual failure point behind kennel banks and in prep bays.

Coved base. For wet areas, safety vinyl is coved up the wall on a cove former and the Jemiclad panel is thermoformed down over it, overlapping by around 50mm, so water runs onto the floor and never behind the wall. For a fully fused finish, the cladding can be hot welded directly to 2mm PVC sheet flooring. Both comfortably exceed the 75mm minimum and neither is stick-on coving.

Installation is carried out by Jemiclad-certified installers who bring the thermoformer to site. A kennel block or theatre can typically be clad in a short programme, often overnight or over a weekend, to keep disruption to a working practice to a minimum. CAD details and the NBS guidance for all three details are on the Technical Documents page.

Walls that pass the assessment and survive the patients

Veterinary walls have to do two jobs: satisfy an RCVS assessor that they are impervious, coved and cleanable, and stand up to animals, cages and chemicals every day for years. Jemiclad hygienic wall cladding, installed seamlessly with a textured scratch-resistant finish where it matters, does both.

Whether you are planning a new animal hospital, refitting a kennel block or preparing for your next PSS assessment, the Jemiclad team can review your room schedule, recommend finishes and details, and connect you with a certified installer. Request samples of the textured white and the colour range, or contact us to discuss your practice.

Frequently asked questions

What does the RCVS require for walls in a veterinary practice? The RCVS Practice Standards Manual requires internal walls and floors of in-patient areas to be impervious so they can be thoroughly cleaned and disinfected, with a coved floor-to-wall junction carried at least 75mm up the wall, flush impervious joints and no stick-on coving. Surgical areas must have easily cleanable surfaces.

Is hygienic wall cladding scratch resistant enough for kennels? Yes, if the right finish is chosen. Jemiclad’s textured white panel is the scratch-resistant option in the range; its fine surface texture hides claw and cage marks that would show on a gloss panel, while staying non-porous and fully washable.

Can veterinary disinfectants damage PVC wall cladding? Jemiclad PVC has good resistance to bleach (sodium hypochlorite), peroxygen and quaternary ammonium disinfectants, acids and alkalis at normal cleaning concentrations. Avoid solvents such as acetone and keep surface temperatures below 60°C.

Does hygienic cladding meet the RCVS 75mm coving requirement? Yes. Jemiclad’s flash cove overlap and welded-to-vinyl details form a continuous coved junction well above 75mm, using a cove former and thermoformed panel rather than stick-on coving.

Can a working veterinary practice be clad without closing? Usually. Certified installers work room by room, and a theatre or kennel block can often be completed overnight or over a weekend.